Woodhead Industries, Inc. applicom® I SST™ I Direct-Link™
I Brad Harrison® I RJ-Lnxx®
APP-SR1-PCI PCI1000
APP-SR1-PCU1 PCU1000
APP-SR2-PCI PCI2000
APP-SR4-PCI PCI4000
5136-SD-PCI-U
APP-PS7-PCI PCI1500S7
APP-PS7-PCU1 PCU1500S7
APP-PFB-PCI PCI1500PFB
APP-PFB-PCU1 PCU1500PFB
APP-PF2-PCI PCI2000PFB
APP-PFB-CPI CPCI1000PFB
APP-ETH-PCU1 PCU2000ETH
APP-EPB-PCU1 PCU2000ETH
APP-ESR-PCU1 PCU2000ETH
APP-FIP-PCI PCI2000FIP
APP-MBP-PCI PCI2000MBP
APP-ESR-GTW GATEway
APP-ESP-GTW GATEway
APP-WEB-SER-M WebGATE
APP-WEB-PFB-M WebGATE
APP-GTW-S4D GT4010
APP-GTW-S4R GT4010R
5136-CN-104
5136-CN-PCI
5136-CN-VME
5136-SD-104
5136-SD-ISA
SST-DHP-PCU
5136-SD-VME
SST-DN3-104-1
SST-DN3-104-2
5136-DNP-ISA
SST-DN3-PCU-1
SST-DN3-PCU-2
SST-DN3S-PCU
5136-DNP-CPCI
5136-DNP-PCM
SST-DN3-VME
SST-PB3-104
SST-DPS-104
SST-PB3-ISA
SST-PB3-PCU
SST-PBMS-PCI
5136-PFB-PCM
SST-PB3-VME
SST-CCS-PCU
DC100DPM-S (Sub-D9)
DC100DPM-H (HE13)
DC100MPI-S (Sub-D9)
SST-PFB-CLX-RLL
SST-PFB-PLC5
SST-PFB-SLC
SST-PFB-SLC-ADP
SST-IBS-CLX-RLL
SST-IBS-SLC
SST-ASI-CMX
SST-ASI-SLC
SST-ASI-CLX
SST-DN3-CNF-P
DeviceNet Configuration
Console, Parallel Key
SST-DN3-CNF-U
DeviceNet Configuration
Console, USB Key
SST-PB3-CNF-P
Profibus Configuration
Console, Parallel Key
SST-PB3-CNF-U
Profibus Configuration
Console, USB Key
SST-DN3-OPC
DeviceNet OPC Server
for SST-DN3 Network Interface Cards
SST-PB3-OPC
Profibus OPC Server
for SST-PB3 Network Interface Cards
SST-PICS-PRO
Full PICS system includes
the DDE client I/O Driver
SST-PICS-PRO requires either
a real-time I/O driver,
the OPC client driver
or the DDE client server
(included) along with any
required interface cards
SST-PICS-PRO-U
Full PICS system, USB Key
SST-PICS-TRN
PICS Pro Training software
SST-PICS-TRN-U
PICS Pro Training software
USB Key
PICS-PRO-AB
PICS Pro Allen-Bradley
Remote I/O Driver
Requires Allen-Bradley
interface cards1:
5136-SD-ISA or SST-DHP-PCI
PICS-PRO-PBMS
PICS Pro Profibus-DP Multi-Slave
I/O Driver
Requires Profibus
interface card1: SST-PBMS-PCI
PICS-PRO-OPC
PICS Pro OPC Server
PICS-PRO-DDE
PICS Pro Wonderware
I/O Servers
WSE-ESV-TSP-A
WSE-ESV-TSP-1
WSE-ESV-TSP-8
WSE-ESV-EDS-1
WSE-ESV-EDS-8
DRL-CNO-PCI PCI-CANIO
DRL-CNO-104 PC104-CANIO
DRL-DVN-PCI PCI-DVNIO
DRL-DVN-104 PC104-DVNIO
DRL-EIO-PCU1 PCU-ETHIO
DRL-ALL-SW SW1000ETH/SER
DRL-MPI-PCU1 PCU100PFB
DRL-2ASI-PFB
DRL-2ASI-SER
DRL-PFB-SRE
DRL-DVN-SRE
DRL-DPM-PCI PCI-DPIO
DRL-DPM-104 PC104-DPIO
DRL-DPM-CPI CPCI-DPIO
DRL-2ASI-PFB
AS-I to Profibus gateway,
2 channels, integrated display
DRL-2ASI-DN
AS-I to DeviceNet gateway,
2 channels, integrated display
DRL-2ASI-CAN
AS-I to CANopen gateway,
2 channels, integrated display
DRL-2ASI-ETH
AS-I to Modbus TCP gateway,
2 channels, integrated display
DRL-2ASI-SER
AS-I to Modbus Serial gateway,
2 channels, integrated display
TCDDN-xxx-10U IP67 Classic 60 mm-M12
TBDDN-xxx-8xU IP67 Compact 30 mm-M12
TBDDN-xxx-8x4 IP67 Compact 30 mm-M8
TDDDN-xxx-10U IP67 Short block
TAS-ANA-xxx IP65 Analog.-M12
TAS-xxx-8E4-00 IP67 Digital-M8
TAS-xxx-CDx-00 IP67 Digital-M12
TEN-888-R18-05 IP67
TCDCC-8D0N-88U Classic block-M12
TCDPB-xxx-B8U Classic block-M12
TBDPB-xxx-B8U Compact block-M12
TBDPB-xxx-B84 Compact block-M8
TCDPB-8D0x-B8U
• 16 input
TCDPB-888x-B8U
• 8 input • 8 output
TCDPB-8C2x-B8U
• 14 input • 2 output
TCDPB-8B4x-B8U
•12 input • 4 output
Compact block M12
TBDPB-480x-B8U
• 8 input
TBDPB-408x-B8U
• 8 output
TBDPB-444x-B8U
• 4 input • 4 output
TBDPB-462x-B8U
• 6 input • 2 output
Compact block M8
TBDPB-880x-B84
• 8 input
TBDPB-808x-B84
• 8 output
TBDPB-844x-B84
• 4 input • 4 output
TBDPB-862x-B84
TCDDN-8D0x-10U
• 16 input
TCDDN-888x-10U
• 8 input • 8 output
TCDDN-8C2x-10U
• 14 input • 2 output
TCDDN-8B4x-10U
• 12 input • 4 output
IP67 Compact 30 mm M12
TBDDN-480x-80U
• 8 input
TBDDN-408x-88U
• 8 output
TBDDN-444x-88U
• 4 input • 4 output
TBDDN-462x-88U
• 6 input • 2 output
IP67 Compact 30 mm M8
TBDDN-880x-804
• 8 input
TBDDN-808x-884
• 8 output
TBDDN-844x-884
• 4 input • 4 output
TBDDN-862x-884
• 6 input • 2 output
IP67 Short block
TDDDN-240P-10U
• 4 input
TDDDN-220P-10U
• 2 output
TDDDN-221P-10U
• 2 input • 1 output
TDDDN-202P-10U
DN-MTR
NetMeter for DeviceNet
DN-MTR-BAG
NetMeter carrying case
DN-MTR-CAL
NetMeter Calibration Testing
715-0016
NetMeter User’s Guide
DN3020PM-1
DeviceNet PowerMonitor®
- Tee - male to female
DN3020PM-3
DeviceNet PowerMonitor®
- Tee - female to male
115011A-PM-1
DeviceNet PowerMonitor®
- in-line - male to female
115011A-PM-3
DeviceNet PowerMonitor®
- in-line - female to male
115011NB-PM-1
DeviceNet PowerMonitor®,
nickel-brass coupling
- in-line - male to female
115011NB-PM-3
DeviceNet PowerMonitor®,
nickel-brass coupling
- in-line - female to male
115011SS-PM-1
DeviceNet PowerMonitor®, `
stainless steel coupling
- in-line - male to female
115011SS-PM-3
DeviceNet PowerMonitor®,
stainless steel coupling
- in-line - female to male
ENHSAURR8
• 8 ports, IP67
DIN Rail Mount Switch
ENHSDURR5
• 5 ports, IP20
ENHSDURS5
• 5 ports, IP20
with fiber optic uplink port
ENHSDURR9
• 9 ports, IP20
ENHSDURS9
• 9 ports, IP20
with fiber optic uplink port
Woodhead Industries, Inc. applicom® I SST™ I Direct-Link™
I Brad Harrison® I RJ-Lnxx®
APP-SR1-PCI PCI1000
APP-SR1-PCU1 PCU1000
APP-SR2-PCI PCI2000
APP-SR4-PCI PCI4000
5136-SD-PCI-U
APP-PS7-PCI PCI1500S7
APP-PS7-PCU1 PCU1500S7
APP-PFB-PCI PCI1500PFB
APP-PFB-PCU1 PCU1500PFB
APP-PF2-PCI PCI2000PFB
APP-PFB-CPI CPCI1000PFB
APP-ETH-PCU1 PCU2000ETH
APP-EPB-PCU1 PCU2000ETH
APP-ESR-PCU1 PCU2000ETH
APP-FIP-PCI PCI2000FIP
APP-MBP-PCI PCI2000MBP
APP-ESR-GTW GATEway
APP-ESP-GTW GATEway
APP-WEB-SER-M WebGATE
APP-WEB-PFB-M WebGATE
APP-GTW-S4D GT4010
APP-GTW-S4R GT4010R
5136-CN-104
5136-CN-PCI
5136-CN-VME
5136-SD-104
5136-SD-ISA
SST-DHP-PCU
5136-SD-VME
SST-DN3-104-1
SST-DN3-104-2
5136-DNP-ISA
SST-DN3-PCU-1
SST-DN3-PCU-2
SST-DN3S-PCU
5136-DNP-CPCI
5136-DNP-PCM
SST-DN3-VME
SST-PB3-104
SST-DPS-104
SST-PB3-ISA
SST-PB3-PCU
SST-PBMS-PCI
5136-PFB-PCM
SST-PB3-VME
SST-CCS-PCU
DC100DPM-S (Sub-D9)
DC100DPM-H (HE13)
DC100MPI-S (Sub-D9)
SST-PFB-CLX-RLL
SST-PFB-PLC5
SST-PFB-SLC
SST-PFB-SLC-ADP
SST-IBS-CLX-RLL
SST-IBS-SLC
SST-ASI-CMX
SST-ASI-SLC
SST-ASI-CLX
SST-DN3-CNF-P
DeviceNet Configuration
Console, Parallel Key
SST-DN3-CNF-U
DeviceNet Configuration
Console, USB Key
SST-PB3-CNF-P
Profibus Configuration
Console, Parallel Key
SST-PB3-CNF-U
Profibus Configuration
Console, USB Key
SST-DN3-OPC
DeviceNet OPC Server
for SST-DN3 Network Interface Cards
SST-PB3-OPC
Profibus OPC Server
for SST-PB3 Network Interface Cards
SST-PICS-PRO
Full PICS system includes
the DDE client I/O Driver
SST-PICS-PRO requires either
a real-time I/O driver,
the OPC client driver
or the DDE client server
(included) along with any
required interface cards
SST-PICS-PRO-U
Full PICS system, USB Key
SST-PICS-TRN
PICS Pro Training software
SST-PICS-TRN-U
PICS Pro Training software
USB Key
PICS-PRO-AB
PICS Pro Allen-Bradley
Remote I/O Driver
Requires Allen-Bradley
interface cards1:
5136-SD-ISA or SST-DHP-PCI
PICS-PRO-PBMS
PICS Pro Profibus-DP Multi-Slave
I/O Driver
Requires Profibus
interface card1: SST-PBMS-PCI
PICS-PRO-OPC
PICS Pro OPC Server
PICS-PRO-DDE
PICS Pro Wonderware
I/O Servers
WSE-ESV-TSP-A
WSE-ESV-TSP-1
WSE-ESV-TSP-8
WSE-ESV-EDS-1
WSE-ESV-EDS-8
DRL-CNO-PCI PCI-CANIO
DRL-CNO-104 PC104-CANIO
DRL-DVN-PCI PCI-DVNIO
DRL-DVN-104 PC104-DVNIO
DRL-EIO-PCU1 PCU-ETHIO
DRL-ALL-SW SW1000ETH/SER
DRL-MPI-PCU1 PCU100PFB
DRL-2ASI-PFB
DRL-2ASI-SER
DRL-PFB-SRE
DRL-DVN-SRE
DRL-DPM-PCI PCI-DPIO
DRL-DPM-104 PC104-DPIO
DRL-DPM-CPI CPCI-DPIO
DRL-2ASI-PFB
AS-I to Profibus gateway,
2 channels, integrated display
DRL-2ASI-DN
AS-I to DeviceNet gateway,
2 channels, integrated display
DRL-2ASI-CAN
AS-I to CANopen gateway,
2 channels, integrated display
DRL-2ASI-ETH
AS-I to Modbus TCP gateway,
2 channels, integrated display
DRL-2ASI-SER
AS-I to Modbus Serial gateway,
2 channels, integrated display
TCDDN-xxx-10U IP67 Classic 60 mm-M12
TBDDN-xxx-8xU IP67 Compact 30 mm-M12
TBDDN-xxx-8x4 IP67 Compact 30 mm-M8
TDDDN-xxx-10U IP67 Short block
TAS-ANA-xxx IP65 Analog.-M12
TAS-xxx-8E4-00 IP67 Digital-M8
TAS-xxx-CDx-00 IP67 Digital-M12
TEN-888-R18-05 IP67
TCDCC-8D0N-88U Classic block-M12
TCDPB-xxx-B8U Classic block-M12
TBDPB-xxx-B8U Compact block-M12
TBDPB-xxx-B84 Compact block-M8
TCDPB-8D0x-B8U
• 16 input
TCDPB-888x-B8U
• 8 input • 8 output
TCDPB-8C2x-B8U
• 14 input • 2 output
TCDPB-8B4x-B8U
•12 input • 4 output
Compact block M12
TBDPB-480x-B8U
• 8 input
TBDPB-408x-B8U
• 8 output
TBDPB-444x-B8U
• 4 input • 4 output
TBDPB-462x-B8U
• 6 input • 2 output
Compact block M8
TBDPB-880x-B84
• 8 input
TBDPB-808x-B84
• 8 output
TBDPB-844x-B84
• 4 input • 4 output
TBDPB-862x-B84
TCDDN-8D0x-10U
• 16 input
TCDDN-888x-10U
• 8 input • 8 output
TCDDN-8C2x-10U
• 14 input • 2 output
TCDDN-8B4x-10U
• 12 input • 4 output
IP67 Compact 30 mm M12
TBDDN-480x-80U
• 8 input
TBDDN-408x-88U
• 8 output
TBDDN-444x-88U
• 4 input • 4 output
TBDDN-462x-88U
• 6 input • 2 output
IP67 Compact 30 mm M8
TBDDN-880x-804
• 8 input
TBDDN-808x-884
• 8 output
TBDDN-844x-884
• 4 input • 4 output
TBDDN-862x-884
• 6 input • 2 output
IP67 Short block
TDDDN-240P-10U
• 4 input
TDDDN-220P-10U
• 2 output
TDDDN-221P-10U
• 2 input • 1 output
TDDDN-202P-10U
DN-MTR
NetMeter for DeviceNet
DN-MTR-BAG
NetMeter carrying case
DN-MTR-CAL
NetMeter Calibration Testing
715-0016
NetMeter User’s Guide
DN3020PM-1
DeviceNet PowerMonitor®
- Tee - male to female
DN3020PM-3
DeviceNet PowerMonitor®
- Tee - female to male
115011A-PM-1
DeviceNet PowerMonitor®
- in-line - male to female
115011A-PM-3
DeviceNet PowerMonitor®
- in-line - female to male
115011NB-PM-1
DeviceNet PowerMonitor®,
nickel-brass coupling
- in-line - male to female
115011NB-PM-3
DeviceNet PowerMonitor®,
nickel-brass coupling
- in-line - female to male
115011SS-PM-1
DeviceNet PowerMonitor®, `
stainless steel coupling
- in-line - male to female
115011SS-PM-3
DeviceNet PowerMonitor®,
stainless steel coupling
- in-line - female to male
ENHSAURR8
• 8 ports, IP67
DIN Rail Mount Switch
ENHSDURR5
• 5 ports, IP20
ENHSDURS5
• 5 ports, IP20
with fiber optic uplink port
ENHSDURR9
• 9 ports, IP20
ENHSDURS9
• 9 ports, IP20
with fiber optic uplink port
PCI-Universal
PC/104
CompactPCI
Brad® applicomIO
PROFIBUS-DP Network
Interface Cards
PCI Express
Brad® applicomIO fieldbus Network Interface Cards
and software provide complete, all-in-one PC-based
control and visualization solutions for high-speed
industrial automation and process-control applications
End-users are increasingly eliminating the use of dedicated DCS (Distributed
Control Systems) and PLC (Programmable Logic Controllers) in favour of PCbased
platforms for control and/ or visualization of their high-speed custom
systems for automation and process-control applications.
applicomIO is a turnkey, all-in-one solution ideal for customers with no/
limited knowledge in fieldbus technology. The applicomIO network interface
card (NIC), configuration software, development libraries and data servers
are provided in one complete package for successful, cost-effective
implementation. applicomIO NICs are designed independently of the
fieldbus used. Customers can take advantage of developing standard control
applications as well as selecting the fieldbus connectivity required from
the applicomIO product range. applicomIO configuration software provides
an user-friendly environment for quick development of communication
applications without the worry of knowing industrial communication protocols.
Time-saving commissioning is supported by features such as automatic device
detection, user configuration management, diagnostic information.
Brad applicomIO network interface cards provide connectivity for all popular
fieldbuses including EtherNet/IP, PROFINET, Modbus TCP, PROFIBUS, DeviceNet
and CANopen in various form factors. applicomIO supports up to 8 cards in a
single PC and can run on various operating systems including Windows, Linux
as well as real-time OS such as VxWorks and RTX.
Product package includes:
• Fieldbus Network Interface Card
• Engineering software console for configuration and diagnostics
• Data Servers (OPC DA v3.0 & v2.05, Wonderware DAServer and FastDDE SuiteLink)
• Development Libraries: Windows (DLL), IntervalZero (RTX)
• Static library for non-windows OS (VxWorks, Linux)
applicomIO hardware and software is 100% designed, developed and
produced in Molex facilities. For additional information visit:
www.molex.com/link/bradnics.html
Brad® applicomIO
PROFIBUS-DP
Network Interface
Cards
112011, 112013, 112018
PCI Universal, PCI Express,
Compact PCI and PC/104 bus
Brad® applicomIO
PROFIBUS-DP
Network Interface
Cards
Robotic Controller
Oil and Gas
Material Handling
Wastewater Treatment
Machine builder
-Robotic controller
-Complex machine
-CNC machine
Factory automation
-Automotive assembly line
-Automotive body shop
-Material handling
Process control
-Wastewater treatment
-Agro food industry
-Oil and Gas
-Pharmaceutical
Applications
applicomIO package includes
Network Interface Card + software
Delivers connectivity for legacy and
new Ethernet fieldbus protocols
including: PROFIBUS DP, CANopen,
DeviceNet, Modbus TCP, EtherNet/IP
and PROFINET
Sophisticated, user-friendly
configuration engineering software
featuring automatic device detection,
user configuration management and
diagnostic information
Protocols run both Master and/or
Slave modes
Can be used on the latest Windows
versions (XP, Seven and Eight) as well
as real-time OS like Linux, VxWorks,
QNX and IntervalZero RTX
Available in PCI, PCI Express, PC/104,
and CompactPCI bus form factors
Single development library
Onboard Ethernet port
Simulation mode
Supports up to 8 cards pl ed in a
single PC
Hardware and software are 100%
designed, developed and produced in
Molex facilities
All-in-One PC-based control solution
for customers with no / limited
knowledge in fieldbus technology
Large range of fieldbus connectivity
to meet needs of customers
Supports quick development of
communication applications; no
knowledge of fieldbus protocols
required. Enables time-saving
commissioning and diagnostics
Allows the card to behave as a
controller or a device on the network
Supports major operating systems
Supports customer requirements with
wide choice of PC form factors
Allows to develop a single user
application for all fieldbus
Enables remote access for
configuration and diagnostics for non-
Windows OS
Allows user application testing
Can connect multiple fieldbus at the
same time
Full technical support and expertise
available from Molex
Features and Benefits
Brad® applicomIO
PCU-DP2IO
Brad® applicomIO
PCIE-DP2IO
Key Benefits
• Fast data exchange (on-board processor take off the load of the host CPU)
• Speed up to 12 Mbps
• Ethernet port for remote configuration and diagnosis
• DP Master and Slave modes simultaneously
Unit PCI-Universal (3.3V/5V) PCI Express 1x
Processor Freescale PowerPC Freescale PowerPC
PROFIBUS ASIC Siemens ASPC2 Siemens ASPC2
Memory 64 Mbytes 64 Mbytes
Flash Memory 16 Mbytes 16 Mbytes
Interruption Hardware Plug&Play Hardware Plug&Play
DPRAM Address Hardware Plug&Play (32 Kbytes) Hardware Plug&Play (32 Kbytes)
Discrete Input 1x Opto-coupled discrete input,
Voltage -> +10 to +24 VDC
1x Opto-coupled discrete input,
Voltage -> +10 to +24 VDC
Discrete Output 1x “WatchDog” output contact free
from potential (floating) (24 VDC, 0.25 A)
1x “WatchDog” output contact free
from potential (floating) (24 VDC, 0.25 A)
Dimensions (LxW) 168mm x 107mm (6.61" x 4.21") 115mm x 97mm (4.58" x 3.82")
Consumption 5.5W (max. 1.2A) 5.5W (max. 1.2A)
Operating T° 0˚C (32˚F) up to +60°C (140°F) 0˚C (32˚F) up to +60°C (140°F)
Storage T° -40˚ C (-40°F) up to +85˚C (185˚ F) -40˚ C (-40°F) up to +85˚C (185˚ F)
EMC EC Directive 2004/108/EC on basis of
compliance with EN 61326-1:2006
EC Directive 2004/108/EC on basis of
compliance with EN 61326-1:2006
Compliances PI Certified, RoHS, FCC, KCC, ICES-003 PI Certified, RoHS, FCC, KCC, ICES-003
Port type 1 PROFIBUS port (EN 50170) 1 PROFIBUS port (EN 50170)
PROFIBUS Connector D-Sub, 9 pin, female D-Sub, 9 pin, female
LED Indicator 2 bicolor LEDs: bus fault and comm. status 2 bicolor LEDs: bus fault and comm. status
Electrical Interface RS485 optical insulation (500 V) RS485 optical insulation (500 V)
Baud Rate 9.6 kbps <-> 12 Mbps 9.6 kbps <-> 12 Mbps
Port Type Ethernet port Ethernet port
Connector type RJ45 RJ45
LED indicators 4 LEDs - TX/RX/Link/100 Mbps 4 LEDs - TX/RX/Link/100 Mbps
Electrical interface Ethernet Ethernet
Speed 10/100 Mbps 10/100 Mbps
Brad® applicomIO
PROFIBUS-DP
Network Interface
Cards
Specifications
HARDWARE
COMMUNICATION PORT
PORT FOR REMOTE CONFIGURATION AND DIAGNOSTIC
Brad® applicomIO
PC104-DPIO
Brad® applicomIO
CPCU-DP2IO
Key Benefits
• Fast data exchange (on-board processor take off the load of the host CPU)
• Speed up to 12 Mbps
• Serial or Ethernet port for remote configuration and diagnosis
• DP Master and Slave modes simultaneously
Unit PC/104 bus CompactPCI 3U bus, 5V
Processor AMD SC520, 100 Mhz Freescale PowerPC
PROFIBUS ASIC Siemens ASPC2 Siemens ASPC2
Memory 8 Mbytes SDRAM 64 Mbytes
Flash Memory 512 Kbytes 16 Mbytes
Interruption 2, 3, 4, 5, 6, 7, 10, 11, 12, 14, 15 Hardware Plug&Play
DPRAM Address From C8000 to DE000
(8 Kbytes used per card) Hardware Plug&Play (32 Kbytes)
Discrete Input 1x Opto-coupled discrete input,
Voltage -> +10 to +24 VDC
1x Opto-coupled discrete input,
Voltage -> +10 to +24 VDC
Discrete Output 1x “WatchDog” output contact free
from potential (floating) (24 VDC, 0.25 A)
1x “WatchDog” output contact free
from potential (floating) (24 VDC, 0.25 A)
Dimensions (LxW) 95mm x 90mm (3.74" x 3.54") 100mm x 160mm (3.93" x 6.29") - 3U
Consumption 5.5W (max. 1.2A) 5.5W (max. 1.2A)
Operating T° 0˚C (32°F) up to +65˚C (149˚F) 0˚C (32˚F) up to +60°C (140°F)
Storage T° -40˚ C (-40°F) up to +85˚C (185˚ F) -40˚ C (-40°F) up to +85˚C (185˚ F)
EMC Compliance EN55022 Class B, EN61000-6-2,
EN61000-3-2, EN61000-3-3
EC Directive 2004/108/EC on basis of
compliance with EN 61326-1:2006
RoHS Compliance RoHS PI Certified, RoHS, FCC, KCC, ICES-003
Port type 1 PROFIBUS port (EN 50170) 1 PROFIBUS port (EN 50170)
PROFIBUS Connector Standard: HE13 (2 x 5 pins)
Option: D-Sub, 9 pin, female D-Sub, 9 pin, female
LED Indicator 2 bicolor LEDs: bus fault and comm. status 2 bicolor LEDs: bus fault and comm. status
Electrical Interface RS485 optical insulation (500 V) RS485 optical insulation (500 V)
Baud Rate 9.6 kbps <-> 12 Mbps 9.6 kbps <-> 12 Mbps
Port Type Asynchronous Serial port Ethernet port
Connector type HE13 (2 x 5 pins) RJ45
LED indicators - 4 LEDs - TX/RX/Link/100 Mbps
Electrical interface RS232 – 2 signals Ethernet
Speed 9600, 38400, 115200 bps 10/100 Mbps
Brad® applicomIO
PROFIBUS-DP
Network Interface
Cards
Specifications
HARDWARE
COMMUNICATION PORT
PORT FOR REMOTE CONFIGURATION AND DIAGNOSTIC
Brad® applicomIO
PROFIBUS-DP
Network Interface
Cards
Protocol Specifications
All Brad® applicomIO networks interface cards for PROFIBUS-DP
support following protocols:
• DP-V0 Master/Scanner Class-1 & -2 and Slave modes simultaneously
• DP-V0 Slave passive mode only
• DP-V1 Master Class-1 & -2 (for PCU / PCIE / CompactPCI cdasr)
Access Modes
DPV0 Master/Scanner Class-1 for optimized exchange of input/output data with the slaves
(Data_Exchange)
DP-V0 Master Class-2 for:
• Slave diagnostics
• Reading inputs/outputs of a slave
• Reading configuration data
• Changing the slave address
DP-V1 Master Class-1 & -2:
• Read Data Block Class 1
• Write Data Block Class 1
• Read Data Block Class 2
• Write Data Block Class 2
• Abort Data Block Comm Class 2
Multi-master mode Yes (able to share the bus with other DP masters connected on the network)
Watchdog control Yes, enables the master to switch into error if no data has been exchanged during this
period (Bus Fault)
Input / Output Data
• Memory of I/O data image:
- PC/104: up to 2Kbytes
- PCI-Universal: up to 8Kbytes
- PCI Express: up to 8Kbytes
- CompactPCI: up to 8Kbytes
• Manage up to 244 data bytes per slave
• Automatic organization of I/O data in the DPRAM memory
Max. DP Slave Connect up to 125 slaves
Data consistency Yes (i.e. user gets the data up to 122 bytes of a slave from one and the same DP cycle)
Data format Direct access to variable types (bit, byte, word, double word)
Local DP slave
• Run simultaneously with Master mode.
• Offers data exchange with another master on the network. The size of the input and
output data is user configurable, and all exchange combinations are possible (from 0
to 244 bytes). The slave can ensure data consistency up to 122 bytes. (see DP-Slave
features below for details)
Access Mode DP-V0 Slave passive (no management of PROFIBUS token)
Input memory size Configurable from 0 to 244 bytes
Output memory size Configurable from 0 to 244 bytes
Slave address Configurable from 0 to 125 by software configuration
GSD files Provided on the CD-ROM
Data Format Configurable Intel or Motorola
Address Assignment Master
(Set_Slave_Address) Not supported
Extended Diagnostic Not supported
DP MASTER FEATURES
DP SLAVE FEATURES
www.molex.com/link/bradnics.html
Order No. 987650-5288 Rev. 1 Printed in EUR/GF/2014.04 ©2014 Molex
Brad® applicomIO
PROFIBUS-DP
Network Interface
Cards
Software Tools
The core of Brad® applicomIO PC Network Interface cards lies in effective
software tools enabling fast integration of industrial communication.
The applicomIO package includes a configuration software console used to set
up card, network and devices connected to the fieldbus. The console performs
dynamic network diagnostic and allows defining access items to the input/
output data used by the software interfaces (OPC server, ActiveX Control,
DAServer, DDE/SuiteLink server).
The console is common to all fieldbuses offered EtherNet/IP, PROFINET, Modbus
TCP, DeviceNet and CANopen. Additional features managed by the console:
• Powerful graphical user interface
• Automatic detection of cards pl ed into the host computer
• User configuration manager: create, backup and restore many user
configurations
• Manual or Automatic device configuration
• PROFIBUS master (automatic configuration by detection of slaves connected)
• GSD library (Add/Remove GSD files)
• Diagnostic monitor; scan devices connected on the bus, able to change DP
slave address
• Card Status indicator: quickly find the initialization status of each card
Device Configuration
PROFIBUS Network Monitoring
Troubleshooting & Testing tool
Order No. Engineering No. Description
112011-5033 DR2-DPM-PCU PCU-DP2IO PROFIBUS-DP Master/Slave 12 Mbps, PCI Universal bus
112011-5034 DR2-DPM-PCU-B25 PCU-DP2IO PROFIBUS-DP Master/Slave 12 Mbps, PCI Universal bus, Bulk of 25 pc
112011-5035 DR2-DPM-PCIE PCIE-DP2IO PROFIBUS-DP Master/Slave 12 Mbps, PCI Express 1x
112018-5005 DR2-DPM-CPU CPCU-DP2IO PROFIBUS-DP Master/Slave 12 Mbps, CompactPCI bus 3U
112013-0003 DRL-DPM-104 PC104-DPIO PROFIBUS-DP Master/Slave 12 Mbps, PC/104 bus, HE13 connector
112013-0005 DRL-DPM-104-B25 PC104-DPIO PROFIBUS-DP Master/Slave 12 Mbps, PC/104 bus, HE13 connector, Bulk of 25 pc
Ordering Information
This document was generated on 06/08/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
Part Number: 1120780001
Status: Active
Description: BradCommunications™ SST™ 4 Serial ports PLC communications module for Allen-
Bradley ControlLogix, includes Remote Link Library feature
Documents:
Drawing (PDF) RoHS Certificate of Compliance (PDF)
General
Product Family Network Interface
Series 112078
Approvals N/A
Communication Speed 110 to 115,200 bps
Mounting Style N/A
Product Name SST™
Protocol DeviceNet* Master/Slave
Type Serial Card
Physical
Channels 4
Interface RS232/RS422/RS485
Network Connection Type D-Sub Female (9 pin)
Packaging Type Carton
Processor PowerPC 8323
Temperature Range - Operating 0°C to +60°C
Electrical
EMC N/A
Supply Voltage 5W
Material Info
Old Part Number SST-SR4-CLX-RLL
Reference - Drawing Numbers
Sales Drawing E-112078-0001
Series
image - Reference only
EU RoHS China RoHS
E nd RoHS
Compliant
REACH SVHC
Not Reviewed
Halogen-Free
Status
Not Reviewed
Need more information on product
environmental compliance?
Email productcompliance@molex.com
For a multiple part number RoHS Certificate of
Compliance, click here
Please visit the Contact Us section for any
non-product compliance questions.
Search Parts in this Series
112078Series
This document was generated on 06/08/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
4 Serial Modbus Channels
For the Allen-Bradley® ControlLogix® Controller
Overview
The BradCommunications™ SST™ Serial module connects Rockwell Automation®
ControlLogix® controllers to Modbus networks. Each module has 4 Serial
communication channels that act as independent Modbus Master or Slave protocols
to exchange data with other Modbus compatible devices.
The SST module acts as a 1756 input/output module between the Modbus network
and the ControlLogix backplane. The data transfer from the SST™ module to the
ControlLogix processor supports 2 modes; a direct mode allowing mapping of
Modbus data in I/O processor image (496 inputs bytes / 496 output bytes) and a
messaging mode (based on CIP transaction) allowing access to Modbus data
images stored in 32K registers of the SST™ module’s memory.
The SST module has a USB port on the front panel which can be used for the
startup of the module when the user configuration is stored to a USB key. This can
also be beneficial if a breakdown occurs, allowing a very quick startup to occur with
a new SST module.
Configuration and Diagnostics
Save your time, the SST module doesn’t require any ladder logic programming to
be used. The configuration is created using a PC-based Windows console software
connected via RLL (Remote Link Library) functionality allowing a remote access to
the SST module for the configuration and the diagnostics through Rockwell network
architectures (Ethernet/ControlNet/DeviceNet™).
The SST console allows the user to define the network parameters, Modbus
devices and the cyclic data exchanges. The console includes a user configuration
manager offering services for download, upload, copy, and rename of user
configurations. With this, a user can very easily and quickly create a new
configuration to initialize and start a SST module.
The SST console includes diagnostic tools to help with the commissioning and
monitoring of the Modbus connection. These tools allow access in read and write
modes to the Modbus slaves or to monitor and modify the module’s internal data
shared bound for a Modbus Master. Thus, the user-friendly tools are available for
controlling the communication in commissioning phase (PROG mode). This same
information is also available in production (RUN mode) through status words
making it possible for the user to manage the execution of the control application in